Show simple item record

dc.contributor.authorBreen, Alex
dc.contributor.authorBreen, Alan
dc.date.accessioned2018-06-25T14:37:06Z
dc.date.available2018-06-25T14:37:06Z
dc.date.issued2016
dc.identifier.citationBreen, A. and Breen, A., 2016 Accuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spine. Medical Engineering and Physics, 38 (7), 607-614 https://doi.org/10.1016/j.medengphy.2016.03.009en
dc.identifier.issn1350-4533
dc.identifier.urihttps://aecc.archive.knowledgearc.net/handle/123456789/34
dc.descriptionAvailable under License - Creative Commons Attribution: https://creativecommons.org/licenses/by-nc-nd/4.0/en
dc.description.abstractQuantitative fluoroscopy (QF) was developed to measure intervertebral mechanics in vivo and has been found to have high repeatability and accuracy for the measurement of intervertebral rotations. However, sagittal plane translation and finite centre of rotation (FCR) are potential measures of stability but have not yet been fully validated for current QF. This study investigated the repeatability and accuracy of QF for measuring these variables. Repeatability was assessed from L2-S1 in 20 human volunteers. Accuracy was investigated using 10 consecutive measurements from each of two pairs of linked and instrumented dry human vertebrae as reference; one which tilted without translation and one which translated without tilt. The results found intra- and inter-observer repeatability for translation to be 1.1 mm or less (SEM) with fair to substantial reliability (ICC 0.533–0.998). Intra-observer repeatability of FCR location for inter-vertebral rotations of 5° and above ranged from 1.5 mm to 1.8 mm (SEM) with moderate to substantial reliability (ICC 0.626–0.988). Inter-observer repeatability for FCR ranged from 1.2 mm to 5.7 mm, also with moderate to substantial reliability (ICC 0.621–0.878). Reliability was substantial (ICC > 0.81) for 10/16 measures for translation and 5/8 for FCR location. Accuracy for translation was 0.1 mm (fixed centre) and 2.2 mm (moveable centre), with an FCR error of 0.3 mm(x) and 0.4 mm(y) (fixed centre). This technology was found to have a high level of accuracy and with a few exceptions, moderate to substantial repeatability for the measurement of translation and FCR from fluoroscopic motion sequences.en
dc.language.isoenen
dc.publisherMedical Engineering and Physicsen
dc.titleAccuracy and repeatability of quantitative fluoroscopy for the measurement of sagittal plane translation and finite centre of rotation in the lumbar spineen
dc.typeArticleen
dc.identifier.doihttps://doi.org/10.1016/j.medengphy.2016.03.009


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record